► Application specific columns utilize novel
and unique chemistries to provide superior 
resolution with ease of use for key pharmaceutical
and environmental applications.
    


Column詳細規格型錄*
*Acclaim AmG C18
Designed to provide rugged and reproducible reversed-phase chromatography of aminoglycoside antibiotics. 
 - Easy to use with only aqueous mobile phase; TFA only, or TFA/HFBA or PFPA is needed
 - Compatible with simple rugged methods; no solvents are required

*Acclaim Trinity P1
Mixed mode column technology combining reversed-phase, anion exchange and cation exchange functionality on a single support.
 
- Ideal selectivity for simultaneous separation of API and counterion
 - Adjustable selectivity by mobile phase ionic strength, electrolyte type, pH, and organic solvent
 - Low bleed; compatible with MS, CAD and ELSD

Acclaim Trinity P2
Mixed-mode column technology; hydrophilic interaction combining HILIC,anion exchange and cation exchange functionalities.
 - Ideal for separating pharmaceutical counterions, including monovalent and divalent cations or anions
 - Selectivity complementary to the Trinity P1 column
 - Low column bleed, compatible with CAD and MS

*Acclaim Organic Acid
Optimized and application-tested for the analysis of hydrophilic organic acids.
 - Compatible with 100% aqueous mobile phases
 - Hydrolytic stability at low-pH conditions

*Acclaim Surfactant
Excellent performance for separating a broad range of surfactants.
 - Ideal selectivity for separation of anionic, nonionic, cationic and amphoteric surfactants 
 - Compatible with highly aqueous mobile phases

*Acclaim Surfactant Plus
Column of choice for surfactant analysis using higher sensitivity detection: performance, versatility, throughput.
 - Ideal selectivity for simultaneous separation of anionic, nonionic, cationic,and amphoteric surfactants
 - Compatible with multiple detectors including MS, CAD, ELSD and UV

Acclaim Explosives E2
The best solution for explosives analysis (EPA Method 8330).
 - Acclaim E2 columns provide baseline resolution of all 14 compounds targeted by EPA Method 8330
 - Columns available in 2.2, 3 and 5μm particle size
 - Simple isocratic elution conditions

*Acclaim Trinity Q1
For trace analysis of diquat and paraquat.
 - LC-MS compatible
 - No ion-pairing reagent needed

Acclaim Carbamate
Designed for baseline separation of carbamate pesticides specified in US EPA Method 531.2.
 - Use with either LC/postcolumn derivatization/fluorescence or LC-MS detection
 - Compatible with both binary (methanol/water) and ternary (acetonitrile/methanol/water) mobile phase gradients

*Acclaim Carbonyl C18
A silica-based, reversed-phase column designed specifically for separating DNPH derivatives of aldehydes and ketones. 
- Ideal selectivity for baseline resolution of DNPH derivatives of aldehydes and ketones regulated by various official methods, including EPA 554,
EPA 8315, EPA 1667, EPA TO-11, and CARB 1004

 

 
-----------------------------------------------------------------------------------------------------------------