*Acclaim 120 C18
The very high surface coverage and very low metal content together result in columns with excellent efficiencies.
- Low silanol activity for excellent peak shapes for basic analytes
- Extremely low bleed, fully compatible with MS
Particle Size |
Pore Size |
Carbon Load |
pH Range |
USP |
2.2, 3, 5 μm |
120Å |
18% |
2-8 |
L1 |
|
*Acclaim 120 C8
The columns are a well-characterized line of LC-MS compatible C8 phases with very high surface coverage
and extremely low silanol activity.
Particle Size |
Pore Size |
Carbon Load |
pH Range |
USP |
2.2, 3, 5 μm |
120Å |
11% |
2-8 |
L7 |
|
|
*Acclaim Phenyl-1
A unique reversed-phase column with high aromatic selectivity
- Unique and complementary selectivity compared to any other phenyl type column
Particle Size |
Pore Size |
Carbon Load |
pH Range |
USP |
3, 5 μm |
120Å |
13% |
2-8 |
L11 |
|
*Acclaim C30
Columns for separating structurally related isomers
- Unique selectivity complementary to other reversed-phase columns
- Compatibility with highly aqueous mobile phase
Particle Size |
Pore Size |
Carbon Load |
pH Range |
USP |
3, 5 μm |
200Å |
13% |
2-8 |
L62 |
|
*Acclaim PolarAdvantage
Acclaim PolarAdvantage (PA) columns feature a patented bonding column chemistry that incorporates
a polar sulfonamide group with an ether linkage near the silica surface.
- Low silanol activity for excellent peak shape with basic compounds
- Compatible with 100% aqueous mobile phase
Particle Size |
Pore Size |
Carbon Load |
pH Range |
USP |
2.2, 3, 5 μm |
120Å |
16% |
2-8 |
L60 |
|
*Acclaim PolarAdvantage II
Complementary selectivity and enhanced hydrolytic stability
- Compatible with 100% aqueous mobile phase
- Wide range of applications
Particle Size |
Pore Size |
Carbon Load |
pH Range |
USP |
2.2, 3, 5 μm |
120Å |
16% |
1.5-10 |
L60 |
|
*Acclaim HILIC-10
Retains highly polar molecules that are not retained by reversed-phase chromatography
Particle Size |
Pore Size |
Carbon Load |
pH Range |
USP |
3, 5 μm |
120Å |
- |
2-8 |
- |
|
*Acclaim Mixed-Mode HILIC-1
Uniquely designed for both reversed-phase and HILIC operations
Particle Size |
Pore Size |
Carbon Load |
pH Range |
USP |
3, 5 μm |
120Å |
- |
2.5-7.5 |
- |
|
*Acclaim Mixed-Mode WAX-1
Designed for separating anionic molecules with powerful adjustable selectivity control
- Multimode retention mechanisms: reversed-phase, weak anion exchange, and HILIC modes
Particle Size |
Pore Size |
Carbon Load |
pH Range |
USP |
3, 5 μm |
120Å |
- |
2.5-7.5 |
L78 |
|
*Acclaim Mixed-Mode WCX-1
Designed for separating cationic molecules with adjustable selectivity control
- Multimode separation mechanism: reversed-phase, weak cation exchange, anion-exclusion and HILIC
Particle Size |
Pore Size |
Carbon Load |
pH Range |
USP |
3, 5 μm |
120Å |
- |
2.5-7.5 |
L85 |
|
*Acclaim Size Exclusion Chromatography (SEC)
Designed for separating cationic molecules with adjustable selectivity control
- SEC-300 calibrated from 100 to 50,000 Daltons
- SEC-1000 calibrated from 1,000 to 1,000,000 Daltons
Particle Size |
Pore Size |
Carbon Load |
pH Range |
USP |
5,7 μm |
300Å (SEC300)
1000Å (SEC1000) |
- |
2-12 |
- |
|
*Acclaim 300 C18
Designed for high-resolution peptide mapping and protein separations
Particle Size |
Pore Size |
Carbon Load |
pH Range |
USP |
3 μm |
300Å |
8% |
2.5-7.5 |
L1 |
|