左側相關訊息
Shodex

SUGAR 系列


Ligand Exchange Chromatography
 - SC1011, SC1821, SP0810, KS-801, KS-802,
   DC-613, SZ5532, SC1211, SC1011-7F

Ion Exclusion Chromatography
 - SH1011,SH1821,KC-811

Features
 

SC1011
SC1821
SC0810
KS-801
KS-802
 
 - Separates saccharides by the combination of ligand exchange and size exclusion mode
 - Three types of counter ions are available: Ca2+, Pb2+, and Na+
 - Only water is required for the analysis of neutral sugars
 - SC1011 and SC1821 correspond to USP L19 and L22
 - SP0810 corresponds to USP L22 and L34
 - KS-801 and KS-802 correspond to USP L22 and L58

 Column詳細資訊 *
 
KS-803
KS-804

KS-805
KS-806

KS-807
 
 - Suitable for separation of polysaccharides by size exclusion mode
 - Can be used in combination with other columns e.g., KS-802 and KS-801
 - Only water is required for the analysis of neutral sugars
 - Corresponds to USP L22 and L58

 Column詳細資訊 *
 

DC-613
SZ5532
SC1211

 
 -
Separates by the combination of ligand exchange and HILIC modes
 - DC-613 can analyze
sugars without removing sodium salts in the sample
 - SZ5532 is recommended for the separation of disaccharides or trisaccharides
 - SC1211 is suitable for separation of sugar alcohols
 - DC-613 corresponds to USP L22 and L58
 - SZ5532 corresponds to USP L22
 - SC1211 corresponds to USP L19 and L22

 Column詳細資訊 *
 
SC1011-7F
 - For the analysis of mannitol under the method of JP, USP and EP
 - Ca-type ligand exchange chromatography column
 - Only water is required for the analysis of neutral sugars
 - Corresponds to USP L19 and L22
 Column詳細資訊 *

 
SH1011
SH1821

 - Columns for simultaneous analysis of saccharides and organic acids
 - Separates neutral sugars in size exclusion mode
 - Separates organic acids in ion exclusion mode
 - Suitable for the analysis of uronic and aldonic acids
 - Corresponds to USP L17 and L22

 Column詳細資訊 *
 
NH2P-50
 - Suitable for saccharides analysis by hydrophilic interaction chromatography (HILIC)
 - Polymer-based packing material provides excellent chemical stability and minimum
   deterioration over extended time period
 - Easily regenerated by washing in a alkaline solution
 - Also suitable for evaporative light scattering detector, corona charged aerosol detector,
   and LC/MS
 - Corresponds to USP L82
 Column詳細資訊 *

 
NH2P-40
 - Provides higher theoretical plate number compared to NH2P-50 series
 - Corresponds to USP L82
 Column詳細資訊 *

 

 

Application

SC1011, 1821: 應用資料
> SP0810: 應用資料
> KS-801 to 802: 應用資料
> KS-803 to 806: 應用資料
> KS-807: 應用資料
> DC-613: 應用資料
> SZ5532: 應用資料
> SC1211: 應用資料
> SC1011-7F: 應用資料
> SH1011,SH1821: 應用資料

> NH2P: 應用資料
> NH2P-LF
: 應用資料

 

-----------------------------------------------------------------------------------------------------------------

**尚有其它系列、規格產品